COST European Cooperation in Science and Technology
By including quasi-RCT, risks of bias in random sequence generation, blinding and allocation concealment must be considered. The first automated CPR systems have been developed just shortly after the description of manual chest compression in the 1960s.79 Therefore, studies of over half a century will have to be assessed, and guideline revisions will have to be considered in the meantime. Any prospective study may be subject to a Hawthorne-like effect, when individuals (in this case, emergency or critical care teams) show a different behaviour due to the knowledge that they participate in a study leading to performance bias in or between intervention and control groups.
Mechanical CPR may represent a method of improving compression quality in certain clinical scenarios and for chosen subpopulations. But can automated mechanical chest compression devices surpass human performance, and again revolutionise CPR? For thousands of years, mankind has struggled to ‘re-animate’ people showing no signs of life. If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service.
The two most common mechanical CPR devices are Load-Distributing Band (LDB), which offers circumferential thoracic compressions, and Piston-Driven (PD), which provides sternal compressions. In recent decades, mechanical chest compression devices have been introduced, and their use is growing. The basic principle of CPR requires manual chest compressions by bystanders and medical personnel.
The reporting of this protocol accords to the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols (PRISMA-P) statement.63 The PRISMA-P checklist is provided as an online supplemental file 1. This has been criticised, as ‘industry sponsored meta-analyses are more likely to recommend an intervention’.33 Moreover, this particular study examined ROSC only, but no long-term outcomes, and included both clinical and animal models. Based on the premise that automated mechanical CPR provides a sustained quality of chest compressions, better outcomes might be expected from these devices.22 Clinical consequences of the introduction of mechanical chest compression in the EMS system for treatment of out-of-hospital cardiac arrest—a pilot study. Implementation of mechanical chest compression in out-of-hospital cardiac arrest in an emergency medical service system.
The primary limitation was the necessity for using observational studies. Because earlier protocols for chest compressions were different from present-day protocols, this would have introduced pipeline bias into the analysis. We synthesized studies performed in the last 20 years only, assuming that the effects of resuscitations can be captured only in the context of guiding protocols. This indicates firm cumulative power from the available literature to support the lack of association between outcome and intervention. Also noteworthy is that the ASPIRE trial had high “other” biases because it was stopped early due to interim evidence of worse outcomes in the intervention arm.12 The studies that had a comparably higher risk of bias in the group failed to control for any confounding factors by design, thereby losing out on the “comparability” score.26 24 The RCTs, however, collectively had a higher risk of bias (Appendix 2).
Primary and secondary outcomes are reported according to the ‘Utstein Style’, a protocol for uniform reporting of resuscitation outcomes,53 and the ‘Core Outcome Set for Cardiac Arrest’,62 based in parts of previous reviews. End-tidal carbon dioxide (etCO2) is considered a surrogate marker for induced cardiac output. Secondary outcomes include short-term and long-term survival, resuscitation trauma and CPR quality surrogates (table 1). The other primary outcome the original reference is the neurological state according to the Glasgow-Pittsburgh cerebral performance category (CPC),54 or modified Rankin score (mRS)55; the association between CPC and mRS is described elsewhere.56 The neurological outcome is evaluated after 30 days, or at hospital discharge.
The actual compensation an individual would require to have their welfare unchanged by a policy is inexact at best. The guiding principle of evaluating benefits is to list all parties affected by an intervention and add the positive or negative value (usually monetary) that they ascribe to its effect on their welfare. In United States regulatory policy, cost–benefit analysis is governed by OMB Circular A-4. The US Clean Air Act has been cited in retrospective studies as a case in which benefits exceeded costs, but knowledge of the benefits (attributable largely to the benefits of reducing particulate pollution) was not available until many years later.
ROSC, which is measured as binary variable, is defined as any spontaneous pulse ‘detectable by manual palpation of a major artery’ at any time following resuscitation attempts.53 This common endpoint in resuscitation studies can be easily obtained and does not depend on a clinical follow-up. Minimum requirements for conventional manual chest compressions include 100–120 vertical compressions per minute of approximately one-third of the sternum height, performed at the middle of chest (caudal third of sternum, intermammary line) in supine position.52 These guidelines are mandatory worldwide and they summarise all the evidence for treatment recommendations and describe the best clinical practice. Until the application of the mechanical CPR device, the patients may have received manual chest compressions as described later. With the progress of modern medicine, even elderly or handicapped people have the potential to recover from an incident with a good quality of life.
In our protocol, the mechanical phase coincided with time-dependent factors—cumulative epinephrine exposure, post-intubation ventilation control, and potential rescuer fatigue during the preceding manual cycles—that could also accelerate lactate clearance. The STROBE flow diagram (Fig. 2) details screening, exclusions, and the analyzed cohort. The baseline demographic and clinical variables, including initial rhythm and total CPR duration, are summarized in Table 1. Consecutive adults (≥ 18 years) who experienced nontraumatic in-hospital cardiac arrest while under observation in the emergency department between 1 December 2023 and 29 February 2024 were eligible if they received at least five complete cycles of CPR. To date, no prospective study has simultaneously evaluated Doppler-derived carotid flow, ETCO₂ and lactate trends during sequential manual and mechanical CPR cycles in adults with in-hospital cardiac arrest. Mechanical compression devices provide constant depths and rates, can be used during patient transport, and can reduce hands‒off intervals .